Cooling water treatment with aquaPROFI filter system
Cooling Water Treatment

Reliable Cooling Water Treatment

Self-cleaning filter systems for the treatment of cooling water circuits. Fully automatic, low maintenance, 24/7 operational reliability. So heat exchangers and instrumentation work reliably for longer.

Scroll

Why aquaPROFI?

Compact filtration with minimal backwash water.

shield

Protection Against Contamination

Precision wire mesh down to 2 µm guarantees clear separation and reliably protects against organics, sediments and suspended solids.

Topmesh screen detail
construction

Minimal Maintenance

Designed for maximum serviceability. Replacement of wear parts without lifting tools and in minutes directly on site.

extension

Modularly Scalable

Filters are not loners.
Redundancy, flexibility and reserve ensure uninterrupted operation and interfaces for growth.

engineering

Engineering Excellence

We deliver not just components, but also mobile complete system solutions for demanding applications.

  • check_circle In-house manufacturing from container adaptation to PLC programming
  • check_circle ISO 9001 Certified
aquaPROFI detail
Operating Principle

Self-cleaning – without interruption

Water flows through the filter element from inside to outside. Dirt particles remain on the inner screen – and are automatically removed.

1

Filtration

Raw water flows through the screen element from inside to outside. Dirt particles remain inside and form a filter cake. The differential pressure rises continuously.

  • check_circle Water flows axially into the screen element
  • check_circle Particles are caught on the inner screen
  • check_circle Differential pressure rises as trigger
AquaPROFI operating principle step 1 – Filtration
AquaPROFI operating principle step 2 – Filter cake formation
2

Filter Cake Formation

The retained particles form a filter cake on the inner screen. The differential pressure rises until the set threshold is reached – then self-cleaning starts automatically.

  • check_circle Filter cake improves fineness
  • check_circle Differential pressure monitoring triggers cleaning
  • check_circle Threshold freely adjustable
3

Self-cleaning

When the differential pressure is reached, the flush valve opens. The motor rotates the suction nozzles in a spiral pattern along the inner screen – the vacuum precisely removes the filter cake.

  • check_circle No interruption of filtrate flow
  • check_circle Vacuum removes dirt precisely across the entire surface
  • check_circle Only 30 seconds flush time and minimal backwash volume
AquaPROFI operating principle step 3 – Self-cleaning with suction nozzles
Field Application

References

Impressions from our cooling water applications – compact and powerful.

Self-cleaning filter system – river water heat pump
zoom_in
Reference 1

Heat Exchanger Protection

Also suitable for systems with low line pressure

Our self-cleaning filters protect heat exchangers from clogging and corrosion, even at low line pressure. For automatic self-cleaning, we integrated a small separate pump here that temporarily increases the flush pressure in the filter housing.

  • water_drop System: Cooling water circuit
  • heat_pump Application: Protection of plate heat exchangers
  • filter_alt Challenge: Automatic cleaning at low line pressure.
  • check_circle Solution: Integrated pump that temporarily increases flush pressure in the housing.
Reference 2

Suspended Dual Filter Installation

Redundant filtration at high flow rates

Two parallel aquaPROFI AP 7025 filters provide redundant filtration at high flow rates. The main cooling water flow is continuously filtered and the maximum particle size in the circuit can be guaranteed.

  • water_drop System: Cooling water circuit
  • heat_pump Application: Reliable removal of particles in the main flow
  • filter_alt Challenge: Cooling reliability must be guaranteed 24/7.
  • check_circle Solution: Dual installation with large filter area in V4A
Dual installation AP 7025 – Two vertical stainless steel filter vessels
zoom_in
AP 7025 filter system during maintenance – filter basket removed
zoom_in
Reference 3

Easy Maintenance in Practice

Filter change without lifting tools in minutes

The AP 7025 in field use: The filter basket can be lifted from the housing without special tools. The generous design allows easy access to all components for inspection and maintenance. All without draining the system.

  • water_drop System: Cooling water circuit
  • construction Application: High flow rate up to 250 m³/h
  • filter_alt Challenge: Easy maintenance on large system
  • check_circle Solution: Vertical installation avoids complete draining, filter basket changeable without lifting tools
Product Overview

The AquaPROFI Series

Four sizes for every flow rate – from compact single-unit to large-scale system.

 AP 725AP 725AP 3025AP 3025AP 5025AP 5025AP 7025AP 7025
Datasheetdownload AP 725download AP 3025download AP 5025download AP 7025
Continuous Filtration (@ ~100 µm)up to 50 m³/hup to 100 m³/hup to 150 m³/hup to 250 m³/h
Filter Area1.000 cm²3.000 cm²5.000 cm²7.000 cm²
Pipe Connection *DN25, DN50, DN80
or 1", 2"
DN80, DN100
or 2"
DN125, DN150DN150, DN250
Screen Fineness2–500 µm (optional, interchangeable)
Backwash Volume30–60 l40–70 l60–90 l90–150 l
Material1.4301 (V2A)  /  1.4571 (V4A)  /  S235JR plastic-coated or powder-coated
Min. Operating Pressure1,5–2,5 bar
Max. Pressure16 bar
Max. Temperature110 °C (55/85 °C with coating)
ControlNone / SIMATIC S7-1200 with Touch Panel / LOGO!
* Additional pipe connections on request