Data center server room with cooling water filtration
Primary Circuit Filtration

Efficient Cooling Water Filtration

Ensure the availability of your infrastructure with aquaPROFI filters. Service-optimized technology for continuous operation and safe commissioning.

Scroll

Why Filter Profitlich?

Outstanding performance for critical infrastructure.

shield

Protection Against Contamination

Precision wire mesh down to 2 µm guarantees clear separation and reliably protects against contamination and deposits.

Topmesh screen detail
construction

Minimal Maintenance

Designed for maximum serviceability. Screen basket replacement without lifting tools and in minutes.

extension

Modularly Scalable

Filters are not loners.
Redundancy, flexibility and reserve ensure uninterrupted operation and interfaces for growth.

engineering

Engineering Excellence

We deliver not just hardware, but system solutions for the most demanding cooling circuits worldwide.

  • check_circle In-house manufacturing from frame to PLC programming
  • check_circle ISO 9001 Certified
Dual basket filter detail
aquaPROFI dual basket filter

Dual Basket Filter – Cost-effective & Reliable

autorenew

No Wear Parts

Manual filter cleaning – no backwash water consumption. Automatic venting ensures no air bubbles enter the piping system.

diamond

Stainless Steel Housing

Manufactured from high-quality stainless steel (1.4301 / 1.4571) for maximum corrosion resistance and durability in demanding environments.
Plastic coating available on request.

speed

High Flow Rates

Modular design allows scaling to virtually any required flow rate for large data centers (Hyperscale).

Manual Alternative

Basket Filter – Cost-effective & Reliable

The manual alternative to our self-cleaning AquaPROFI filters. Same housing concept, same quality – without automation.

water_drop

Filter Fineness

1–1000 µm

Washable and freely interchangeable screen baskets

speed

Throughput

up to 250 m³/h

Per filter size

compress

Operating Pressure

10 bar

-10 °C to +110 °C

Type Overview – Standard Sizes

Filter area and throughput depending on size

TypeFilter AreaThroughput from 100 µmØ mmHeight mmPipe Connection
TF 130 111s1.200 cm²100 m³/h100434R1"–DN125
TF 130 112s1.900 cm²150 m³/h120530R2"–DN125
TF 130 113s3.500 cm²200 m³/h158710DN80–DN125
TF 130 114s5.200 cm²250 m³/h211806DN100–DN125
savings

Cost-effective

Manual alternative to self-cleaning systems – no automation, no compromises in filter performance.

handyman

Maintenance-friendly

Quick-release or ring nuts – no special tools. Pull out the basket, rinse, reinsert.

electrical_services

No Power Required

No electrical connection needed. Ideal for simple applications or as a backup filter.

call_split

Redundancy

As a dual filter in parallel – one filter stays in operation while the other is cleaned.

Housing Material

  • check S235JR powder-coated
  • check Stainless steel 1.4301 (V2A)
  • check Stainless steel 1.4571 (V4A)
  • check Screen mesh 1.4401 / 1.4404

Accessories

  • check Differential pressure indicator (mechanical)
  • check Differential pressure sensor (electrical)
  • check Shut-off flaps: manual, electric or pneumatic
  • check Dual filter arrangement for redundant operation
Application Areas

Confidence Through Experience

Whether closed or open, primary or secondary circuit – aquaPROFI filters reliably in any cooling water architecture.

Closed Circuits

Demineralized Water · Glycol Mixtures · Secondary Circuits

water_drop

Demineralized Water & Mixtures

Fully demineralized water and glycol-water mixtures in closed primary circuits. Fine filtration from 2 µm protects cold plates, CDUs and heat exchangers.

swap_horiz

Secondary Circuit (District Heating)

In district heating networks, heat is fed back from the DC. We keep the secondary medium free of particles and deposits – for stable transfer points.

shield

Rouge and Corrosion Protection

In closed systems, our filters prevent rouge formation and corrosion products before they clog microchannels and nozzles.

Open Circuits

Well Water · Surface Water · Cooling Towers

waves

Well & Surface Water

Raw water brings dirt, algae and organic load. Our aquaPROFI filters clean in continuous operation – self-cleaning, without process interruption.

ac_unit

Cooling Tower Feed & Return

Open cooling towers draw in environmental contamination. Filtration in the feed prevents deposits, in the return biological growth is controlled.

opacity

Scale & Biofilm Prevention

Open systems tend to scale and biofilm formation. Self-cleaning screens keep flow constant and reduce chemical water treatment.

water_pump

Main Flow Filtration

Filter directly in the main circuit. 100% of the flow is filtered – no bypass. OCP-compliant for critical primary circuits.

alt_route

Side-Stream Filtration

Side-stream: A partial flow is continuously diverted, filtered and returned. Ideal for large volumes and open circuits.

play_circle

Commissioning Filter Rack

Separate filter rack for commissioning and flushing only. Cleans the circuit before operation, then removed. Purchase, rental or leasing.

Purchase · Rental · Leasing
verified_user
verified_user

OCP Compliant

We follow the experiences in the Open Compute Project and support the guidelines and recommendations.

Ready for Maximum Uptime?

Our project engineers will gladly advise you on designing the optimal filtration strategy for your data center.